iOffice AutoCAD p-line standard requirements are as follows:

 

  1. Processed drawing should have all interior, & exterior building walls and room fixtures.

    • Remove all ancillary layers and attributes from drawing including electrical and mechanical layers - leaving base exterior walls, interior walls, fixtures, common areas and furniture.

 

  1. Explode & isolate all Lobby, common area, break area, conference room, training room, fitness center, cafeteria, meeting space, and work room furniture, equipment & files and assign furniture and files to the following layer names:

    • !FURN

    • !FILES

 

  1. iOffice P-Line, Boundary, Floor & Room Layers should be named and colored as follows:

    • !A-AREA-SPACE (blue)

    • !A-AREA-FLOOR (orange)

    • !A-AREA-ROOM# (teal)

    • !BOUNDARY (red)

 

  1. Isolate and explode all systems furniture (cubicle) panels and connectors and assign to the following layer:

    • !PANELS

 

  1. Isolate and explode all systems furniture (cubicle) work surfaces, and private office furniture and assign to the following layer:

    • !WKST

 

  1. Workstations (cubicles) should display panel walls surrounding an empty, p-lined workstation area

    • Ensure p-lines connect to all interior points and are closed.

    • For octagonal furniture pods please ensure p-lines are symmetrical in shape and align with uniform aisles and corridors.

    • If large floor plate; delete cubicle accessories & seating to help reduce drawing file size.

 

  1. P-lined Offices should be empty of all furniture (Furniture should be assigned to the !WKST layer and turned off)

    • Ensure p-lines connect to all interior points and are closed.

 

  1. Common Area and Meeting spaces will display seating and furniture within the p-lined room.

 

  1. Burst all room blocks and delete any extra attributes - leaving room number as a text entry that will be assigned to the !A-AREA-ROOM# layer.

    • All room identifiers will be text entries.

 

  1. Unlock, unfreeze, and turn on all drawing layers and make all layers black (color 250)

    • Except for color used for iOffice layers, all other drawing layers will be in Color 250.

 

 